Professional production and processing of high-precision Machine element

 

Disposable endoscopic flexible tissue sampling forceps

  • Categories:NEWS
  • Author:
  • Origin:
  • Time of issue:2019-09-26 10:17
  • Views:0

(Summary description)Intended use: This device is mainly used for extracting live tissue samples from the digestive tract and respiratory tract under endoscopy. Product features: The clamp head is made of medical stainless steel, and the head is carefully polished to minimize damage to the clamp hole

Disposable endoscopic flexible tissue sampling forceps

(Summary description)Intended use: This device is mainly used for extracting live tissue samples from the digestive tract and respiratory tract under endoscopy. Product features: The clamp head is made of medical stainless steel, and the head is carefully polished to minimize damage to the clamp hole

  • Categories:NEWS
  • Author:
  • Origin:
  • Time of issue:2019-09-26 10:17
  • Views:0
Information

Intended use: This device is mainly used for extracting live tissue samples from the digestive tract and respiratory tract under endoscopy.

Product features:

The clamp head is made of medical stainless steel, and the head is carefully polished to minimize damage to the clamp hole;

The blade is specially treated, sharp, with good fit, and easy and reliable sampling;

Laser welding is adopted, with high component connection strength;

The spring tube can be coated with super smooth plastic, effectively reducing damage to the clamp hole;

Optimized design of the operating handle, clear top and bottom stops, and comfortable hand feel;

Sterilized packaging, disposable.

The disposable endoscopic flexible tissue sampling forceps are composed of needle tip (06Cr19Ni10), clamp head (05Cr17Ni4Cu4Nb), spring tube (06Cr19Ni10), plastic coating (PE), cable (06Cr19Ni10), slip ring, handle (), and protective sleeve (TPE). They are divided into several specifications according to the applicable clamp hole diameter, work length, clamp head characteristics, whether plastic coating is applied, and whether needle is used. Basic parameters: Connection strength: capable of withstanding a tensile force of 30N for 10 seconds; The opening angle of the clamp head two pieces shall not be less than 90 °; Clamp head hardness ≥ 245HV0.2; Surface roughness: Ra not greater than 0.8 μ M; Corrosion resistance: The outer surface shall not be lower than level b, and the rest shall not be lower than level c. The product is sterilized with ethylene oxide and should be sterile.